Amazines Free Article Archive
www.amazines.com - Wednesday, April 17, 2024
Read about the most recent changes and happenings at Amazines.com
Log into your account or register as a new author. Start submitting your articles right now!
Search our database for articles.
Subscribe to receive articles emailed straight to your email account. You may choose multiple categories.
View our newest articles submitted by our authors.
View our most top rated articles rated by our visitors.
* Please note that this is NOT the ARTICLE manager
Add a new EZINE, or manage your EZINE submission.
Add fresh, free web content to your site such as newest articles, web tools, and quotes with a single piece of code!
Home What's New? Submit/Manage Articles Latest Posts Top Rated Article Search
Google
Subscriptions Manage Ezines
CATEGORIES
 Article Archive
 Advertising (133573)
 Advice (161671)
 Affiliate Programs (34799)
 Art and Culture (73855)
 Automotive (145712)
 Blogs (75614)
 Boating (9851)
 Books (17223)
 Buddhism (4130)
 Business (1330636)
 Business News (426446)
 Business Opportunities (366518)
 Camping (10973)
 Career (72795)
 Christianity (15848)
 Collecting (11638)
 Communication (115089)
 Computers (241951)
 Construction (38962)
 Consumer (49953)
 Cooking (17080)
 Copywriting (6733)
 Crafts (18203)
 Cuisine (7549)
 Current Affairs (20319)
 Dating (45908)
 EBooks (19703)
 E-Commerce (48258)
 Education (185520)
 Electronics (83524)
 Email (6438)
 Entertainment (159854)
 Environment (28970)
 Ezine (3040)
 Ezine Publishing (5453)
 Ezine Sites (1551)
 Family & Parenting (111007)
 Fashion & Cosmetics (196605)
 Female Entrepreneurs (11853)
 Feng Shui (134)
 Finance & Investment (310615)
 Fitness (106469)
 Food & Beverages (63045)
 Free Web Resources (7941)
 Gambling (30227)
 Gardening (25202)
 Government (10519)
 Health (630137)
 Hinduism (2206)
 Hobbies (44083)
 Home Business (91657)
 Home Improvement (251210)
 Home Repair (46243)
 Humor (4723)
 Import - Export (5459)
 Insurance (45104)
 Interior Design (29616)
 International Property (3488)
 Internet (191029)
 Internet Marketing (146687)
 Investment (22861)
 Islam (1161)
 Judaism (1352)
 Law (80506)
 Link Popularity (4596)
 Manufacturing (20914)
 Marketing (99316)
 MLM (14140)
 Motivation (18233)
 Music (27000)
 New to the Internet (9496)
 Non-Profit Organizations (4048)
 Online Shopping (129734)
 Organizing (7813)
 Party Ideas (11855)
 Pets (38165)
 Poetry (2229)
 Press Release (12689)
 Public Speaking (5643)
 Publishing (7566)
 Quotes (2407)
 Real Estate (126700)
 Recreation & Leisure (95495)
 Relationships (87674)
 Research (16182)
 Sales (80350)
 Science & Technology (110290)
 Search Engines (23514)
 Self Improvement (153300)
 Seniors (6220)
 Sexuality (36010)
 Small Business (49311)
 Software (83033)
 Spiritual (23516)
 Sports (116155)
 Tax (7663)
 Telecommuting (34070)
 Travel & Tourism (308304)
 UK Property Investment (3123)
 Video Games (13382)
 Web Traffic (11790)
 Website Design (56919)
 Website Promotion (36663)
 World News (1000+)
 Writing (35844)
Author Spotlight
TAL BARNEA

Tal is an electrical engineer with over 25 years of expertise with hardware, software, mechanical an...more
MANMOHAN SINGH

Digital marketing professional with 8 years of experience. A good listner, Stratgist and fun loving ...more
LEMUEL ASIBAL

Lemuel Asibal is a web content writer who also ventures on writing articles and blog posts about any...more
TUSHAR BHATIA

Tushar Bhatia is the Founder President of EmpXtrack Inc with over 19 years of experience in the soft...more
BRENDA PANIN

Passionate blogger and a great animal lover. ...more


Ventilation and Air Exhaust Systems by Oleg Chetchel





Ventilation and Air Exhaust Systems by
Article Posted: 02/23/2012
Article Views: 84
Articles Written: 120
Word Count: 884
Article Votes: 0
AddThis Social Bookmark Button

Ventilation and Air Exhaust Systems


 
Advice,Business,Business Opportunities
Ventilation and air exhaust systems are designed to capture airborne chemicals at the source of generation and remove contaminants from the work area. When a local exhaust system does its job your workers are healthy and productive. It usually consists of:

- hoods for capturing the contaminant

- ducts for transporting the contaminant

- air cleaner for removing contaminants from the air stream

- fan to create airflow in the system

- stack to discharge the air outside the workplace.

HOOD DESIGN

A well-designed hood is the most important component of an effective LEVS. The hood must be positioned so that it does not pull contaminated air through the worker's breathing zone. It should be easy to use and not interfere with the job that the worker is trying to do. It should be positioned as close to the point of contaminant generation as possible. The further it is from the point where the chemical is released into the air, the more airflow is required to capture the contaminant.

AIR VOLUME AND CAPTURE VELOCITY

The air volume (cubic feet per minute) that must be exhausted by LEVS is determined by the type of hood, the distance of the hood from the source of the contaminant and the velocity needed to capture the contaminant (Capture Velocity). Capture velocity for a hood is determined by the properties of the chemical and how it is being used. Examples of capture velocities are shown in Table 1.

MAKE UP AIR

Air will only be exhausted to the extent that air enters the workplace. If you don't provide make up air in the amount at least equal to the amount of air being exhausted, your LEVS will not work properly and the workplace will be very drafty, doors will be difficult to open, and furnaces, heaters or other combustion equipment may back draft.

TRANSPORT VELOCITY AND DUCT SIZE

Once a contaminant is captured by the hood it moves into the duct system. The velocity in the duct must be sufficient to transport the contaminant through the LEVS. The velocity in the duct necessary to carry the contaminant through the system is referred to as the transport velocity. The heavier the contaminant the higher the velocity needed for transport. Some examples of transport velocities for different contaminants are shown in Table 2. Once you know the airflow volume and transport velocity needed for a LEVS, the duct size can be calculated using the formula shown in Table 3.

sTREAMLINE AIR FLOW

Local exhaust systems should always use round ducts, because airflow is more uniform and streamlined, which makes the system more efficient and provides better transport for contaminants. The duct runs should be as straight as possible; curves should be smooth and gradual; and an elbow should have a radius of 2 to 2.5 times the duct diameter. Branch entries into the main duct should be at an angle of 45?; there should be no 90? entries. All changes in size should be smooth and gradual.

STACKS

A stack should discharge contaminated air vertically upward and away from the building. Stacks should be located as far from air intake units as possible to prevent reintroduction of contaminated air into the building. The top of the stack should be 1.3 to 2 times the building height above the ground. Avoid exhausting air out of the sides of buildings. The pressure of prevailing winds blowing into the exhaust can severely affect the performance of the LEVS.

FAN SELECTION

The fan you select for your LEVS should be based on the needs of the system. It should not only deliver the volume of air (in cubic feet per minute) necessary to capture the contaminant but be able to do so against the resistance to airflow in the system. The resistance to airflow is measured in inches of water and is usually referred to as static pressure losses. Static pressure losses in LOCAL EXHAUST SYSTEM are determined by the:

- size of the duct,

- roughness of the duct material,

- number and type of elbows, entries, and changes in size,

- type of air cleaner,

- type of hood,

- volume of air flowing in the system,

- stack design. It should be clear from this list that a fan cannot possibly be selected successfully until the system has been designed.

SYSTEM INSTALLATION

Insist that you get a system installed as designed, with round ducts and smooth streamlined airflow. Since a rough duct increases static pressure losses and requires a larger fan, you should keep the use of a flexible duct, which is very rough, to a minimum. Use a flexible duct only where you need flexibility and use as little of it as possible.

Fans will operate more efficiently if they are installed with a length of straight duct entering and leaving the fan. A rule of thumb is to provide a straight run of duct at least six duct diameters long on the entrance side of the fan and at least two duct diameters long on the exit side. After installing the system, measure to ensure that the LEVS delivers the airflow volume and velocity that is needed to do the job.

For additional information please refer to http://olegsystems.com/fumeextractor/Index.html.

Oleg Chetchel Industrial Process Ventilation Designer NIS Systems Co. http://olegsystems.com/dustcollector/Index.html http://olegsystems.com/scrubber/Index.html

Related Articles - local, exhaust, ventilation, ventilating, capture, dust, collector, collecting, collection, air, cleaning, cyclone, scrubber, wet, gas, fume, extractor, ventilator, fan,

Email this Article to a Friend!

Receive Articles like this one direct to your email box!
Subscribe for free today!

 Rate This Article  
Completely useless, should be removed from directory.
Minimal useful information.
Decent and informative.
Great article, very informative and helpful.
A 'Must Read'.

 

Do you Agree or Disagree? Have a Comment? POST IT!

 Reader Opinions 
Submit your comments and they will be posted here.
Make this comment or to the Author only:
Name:
Email:
*Your email will NOT be posted. This is for administrative purposes only.
Comments: *Your Comments WILL be posted to the AUTHOR ONLY if you select PRIVATE and to this PUBLIC PAGE if you select PUBLIC, so write accordingly.
 
Please enter the code in the image:



 Author Login 
LOGIN
Register for Author Account

 

Advertiser Login

 

ADVERTISE HERE NOW!
   Limited Time $60 Offer!
   90  Days-1.5 Million Views  

 

Great Paranormal Romance


LAURA JEEVES

At LeadGenerators, we specialise in content-led Online Marketing Strategies for our clients in the t...more
TIM FAY

After 60-plus years of living, I am just trying to pass down some of the information that I have lea...more
ALEX BELSEY

I am the editor of QUAY Magazine, a B2B publication based in the South West of the UK. I am also the...more
GENE MYERS

Author of four books and two screenplays; frequent magazine contributor. I have four other books "in...more
SUSAN FRIESEN

Located in the lower mainland of B.C., Susan Friesen is a visionary brand strategist, entrepreneur, ...more
STEVERT MCKENZIE

Stevert Mckenzie, Travel Enthusiast. ...more
STEPHEN BYE

Steve Bye is currently a fiction writer, who published his first novel, ‘Looking Forward Through the...more
SHALINI MITTAL

A postgraduate in Fashion Technology. Shalini is a writer at heart! Writing for her is an expression...more
ADRIAN JOELE

I have been involved in nutrition and weight management for over 12 years and I like to share my kn...more
JAMES KENNY

James is a Research Enthusiast that focuses on the understanding of how things work and can be impro...more

HomeLinksAbout UsContact UsTerms of UsePrivacy PolicyFAQResources
Copyright © 2024, All rights reserved.
Some pages may contain portions of text relating to certain topics obtained from wikipedia.org under the GNU FDL license