Eleventh National Games approached, May 13, the Eleventh National Games gymnastics preliminaries & 2009 National Gymnastics Championships will be held in Jinan Olympic Sports Center Gymnasium. Olympic Sports Center Gymnasium how fire safety is deployed? How to do fire safety and evacuation of personnel in a timely manner? Issues of concern to the reader, the reporter interviewed the fire department in Jinan. Evacuation diagram Fire: According to the fire emergency plan for four Key positions under the stadium fire-prone location of the fire will be set to three venues, namely, fire grade , grade fire, grade fire; fire as the highest-level fire, the lowest level fire fire. Fire rescue action Games venues Fire The fire fighting and rescue operations in accordance with the fire rating, the implementation of "one minute fire-fighting operations," the "three-minute fire-fighting operations," the "five-minute fire-fighting action" and "10 minutes fire-fighting operations program." The event of fire level, the immediate opening of the "one minute, three-minute fire-fighting action plan" on-site fire fighting operations should be completed within a minute. When the fire occurred when the grade , immediately enable the "three-minute fire-fighting action": a recent on-site duty firefighters arrived at the scene, using the knapsack Class A Foam Devices, water mist fire extinguishers, fire fighting operations are deployed to the scene in "three minutes" to complete. In case of grade fire, the immediate opening of "five-minute fire-fighting action": immediate start on site on duty or the use of fixed fire extinguishing facilities, fire fighting, fire scene commander in chief command of the scene. Deployment of fire fighting action scene in "five minutes" to complete; when the fire beyond the on-site fire fighting capabilities on duty forces, the immediate opening of "10 minutes fire-fighting action": on-site fire fighting and rescue duties, while the rapid adoption of " 119 "Fire Command Center to mobilize around the fire station of the designated fire service emergency admission to reinforce the surrounding fire station in accordance with the specified fire fighting and rescue forces to enter the scene in coordination plan. Live fire fighting operations are deployed in the" 10 minutes "to complete. In the fire fighting process, gymnasium Fire Hydrant Water supply systems, fixed fire monitor system will play a role. Escape: floors are evacuated channel Stadium stands at the upper and lower sides of settings. Stands for the evacuation of the upper down-type way, the audience seats down from the stands by 12 export evacuated to the 4th floor hall audience distribution, can then be evacuated six nearby stairs and along the two escalators down to Level 2 evacuation of the audience hall distribution , and then through 2 layers of exports in the evacuation to the evacuation of a large outdoor platform. What part of the lower grandstand type evacuated by way of the Bank of China, north and south part of the stand by way of upward evacuation. The audience stands through the export of the 16 evacuated to two distribution layer audience hall, and then through exports, to reach out directly to the audience with the evacuation of a large outdoor level platform, platform, audience, respectively, from the East, Southwest, Northwest continued outward in three directions evacuation, evacuation to the outside by walking the ground channel. Disabled visitors can go directly from the grandstand area hall 2 layer distribution, and then evacuated to a large platform outside. Layer of mainly three exits: the safety of exports outside the hall and through north and south sides of the evacuation channel. Within the field of two-story evacuation channel (export) 16, field evacuation channel (export) 12. The audience may be 201-216 in a total of 16 export evacuated to outlying regions, peripheral areas 12 exit leading to the outdoor plaza area, outdoor plaza area with the East, Northwest, Southwest will continue to evacuate the three directions. A total of four elevators three and four closed stairwell. Evacuation of personnel from within the box out of the room after evacuation of nearby stairs to the second floor along the hall, 301,302,303,304, and then select the export evacuated to the nearest outdoor platform. There are 12 evacuation four channels will be the audience within the audience was evacuated to a rest room, 10 o'clock direction (north west) to Exit 1, in accordance with the counter-clockwise order, followed by entry No. 1-12; five 4 one evacuation channel, distributed in the northeast, southeast, northwest, southwest stairwell leading to the 1-6. Lighting: Lighting backup electricity supply by 2 Road Central control room, fire-fighting equipment, fixed Communicate Room and other important room, power distribution room, VIP area lighting and normal lighting unity reserve, in normal lighting Power supply Failure power outage, can maintain normal lighting illumination. Standby lighting electricity supply by 2 Road, dual power at the end automatically. Staircase, staircase before the room smoke evacuation corridors, exit and other areas with evacuation evacuation lighting and signage. To ensure the safety of athletes and spectators and to avoid panic and dangerous, in the venue and the audience set the security lighting. Security lighting electricity supply by 2 way, dual power supply end of the automatic switch. Smoke: roof layout of 4 units Exhaust fan Gymnasium with mechanical smoke extraction system, the uniform layout of the 4 sets of roof exhaust fan, exhaust volume per 90000m3 / h. Each box on the balcony level mechanical exhaust. Competition open hall at the top center with electric sunroof, fire, smoke as a fire, usually as a natural ventilation. Basketball and gymnastics training field to open the lateral wall with electric sunroof, fire, smoke as a fire, usually as a natural ventilation. Fire, the inner office, within the corridors under the Fire Control Centre commands automatically open the corresponding partition of the normally closed electric smoke exhaust port and the linkage to open the corresponding partition of the exhaust smoke exhaust fan. We are high quality suppliers, our products such as lock picking tool , auto opening tools for oversee buyer. To know more, please visits lock picking tools.
Related Articles -
lock picking tool, auto opening tools,
|